Verified by the CalcTree engineering team on July 14, 2024
This calculator designs timber members in bending, like rafters and joists, by ensuring the beam meets flexural and shear requirements to Ultimate Limit State (ULS) methods.
All calculations are performed in accordance with AS 1720.1-2010.
As per AS1720.1 Clause 3.2.4, k12 considers the stability of the member.
For bending, as per AS1720.1 Clause 3.2.4, k12 considers the effect of lateral and torsional restraints and member slenderness. The spacing of the lateral and torsional restraints govern how the member buckles under load, which affects its capacity.
k12 is given by:
S1
:10.758287072798359
The slenderness factor for bending about the major axis, S1, is calculated differently depending on how the member is restrained: