This calculator allows the user to assess the structural integrity of timber columns to ensure compliance with the Australian Standard AS 1720.1:2010. The calculation will identify the design capacities of timber columns to meet flexural, shear and deflection design requirements to Ultimate Limit State (ULS) and Serviceability Limit State (SLS) methods.
❗This calculation has been written in accordance with AS1720.
Calculation
⬇️ Inputs
Material Properties
Seasoned or unseasoned
:Seasoned
Type of timber material
:GLT
Application of structural member
:Category 1
Characteristic Values
Loads
Section and Member Geometry
⬆️ Outputs
Section Properties
Strength group
:S6
Joint group
:J4
Design density (kg/m3)
:800
Gross cross-sectional area (Ag)
:90000mm2
Section modulus (Z)
:4.500e+6mm3
Moment of inertia, Ixx (mm4)
:6.750e+8
Design Capacities
Modification Factor details
💬 We'd love your feedback on this template! It takes 1min
Explanation
Timber Properties
Australian Standards set out guidelines and minimum requirements for material properties, design parameters, design procedures and calculation methods. Here, we explain some pertinent timber properties that should be considered carefully when undertaking timber design calculations.
☀️ Seasoning
🌳 Types
🎓 Stress Grade
Design Properties of Structural Timber Elements
Design capacities for all structural timbers are obtained by modifying characteristic capacities with factors appropriate to service conditions and material property type. This process applies to all types of timber.
Member Design Capacity
Characteristic values (f'o)
Capacity Factor (ϕ)
Geometric Properties (X)
Modification Factors (kmod)
Checking Limit States
AS1720.1 provides guidelines for Ultimate Limit State (ULS) design. The calculation methods for design forces and capacities of structural timber members, joints and fasteners are robust enough to account for different scenarios and environmental factors. According to AS1720 Clause 2.1.2 and 2.1.3, the design capacities of members and joints must satisfy the following (right).
Permissible allowable stress limits or design limit c
apacities of timber columns are then calculated for each check by multiplying the relevant characteristic properties, modification factors and geometric properties together:
💬 Got 1min to provide feedback on this template? Click here